ABO Test Prep

ABO Formula Sheet

Reviewed by Beau Wall, ABOC ·

The formulas for the optics and dispensing math on the ABO exam (the NOCE), each with a worked example, on one sheet of paper printed front and back. It's free and there's nothing to sign up for: print it or save it as a PDF. Each formula links to its calculator or study guide.

Lens power and prescriptions

Focal length and lens power

F = 1 ÷ f

f = 1 ÷ F

F in diopters, f in meters. An add focuses at 1 ÷ add.

Example: A +2.50 D lens focuses at 1 ÷ 2.50 = 0.40 m (40 cm); a +2.50 add reads at the same 40 cm.

Ophthalmic lenses →

Nominal lens power

F = F₁ + F₂

Front surface power plus back surface power.

Example: +6.00 D front, -8.00 D back: +6.00 + (-8.00) = -2.00 D.

Ophthalmic lenses →

Transposition

New sphere = sphere + cylinder

New cylinder = same amount, opposite sign

New axis = axis ± 90° (kept between 1 and 180)

Example: -0.75 +1.25 × 170 becomes +0.50 -1.25 × 080.

Transposition calculator →

Spherical equivalent

SE = S + C ÷ 2

Add half the cylinder to the sphere, keeping the signs.

Example: -2.25 -1.50 × 090: SE = -2.25 + (-1.50 ÷ 2) = -3.00 D.

Spherical equivalent calculator →

Power in any meridian (sin² rule)

F(θ) = S + C × sin²(θ − axis)

θ is the meridian you want. Use the 180° power for horizontal decentration and the 90° power for vertical.

Example: -1.00 -2.00 × 030: at 180°, -1.00 + (-2.00 × 0.25) = -1.50 D; at 90°, -1.00 + (-2.00 × 0.75) = -2.50 D.

Prescription (Rx) interpretation →

Near prescription

Near sphere = distance sphere + add

The cylinder and axis do not change.

Example: -2.25 -0.75 × 015 with a +2.00 add: near Rx -0.25 -0.75 × 015.

Prescription (Rx) interpretation →

Vertex distance

Fc = F ÷ (1 − d × F)

d is the reduction in vertex distance in meters: positive when the lens moves closer to the eye. Compensate powers over ±4.00 D; for a sphero-cylinder, compensate each principal meridian, then recombine.

Example: -6.50 D at 12 mm, as a contact lens: -6.50 ÷ (1 − 0.012 × -6.50) = -6.03 D, about -6.00 D.

Vertex distance calculator →

Prism

Prentice's rule

Δ = c × F

Δ in prism diopters, c = decentration in centimeters (mm ÷ 10), F = power in the meridian of the decentration.

Example: +2.50 D, optical center 5 mm in: 0.5 × 2.50 = 1.25Δ base in.

Prentice's rule calculator →

Base direction

Plus lens: base points toward the optical center

Minus lens: base points away from the optical center

Judge it from where the optical center sits relative to the pupil. The base always points toward the thicker part of the lens.

Example: -4.50 D, optical centers 3 mm out: 0.3 × 4.50 = 1.35Δ base in per eye.

Prism and Prentice's rule →

Compounding prism

R = √(H² + V²)

Angle from the horizontal = arctan(V ÷ H)

Then write the angle in 360° notation for that eye (see resolving prism).

Example: 2.00Δ BI with 1.50Δ BD: R = √(2.00² + 1.50²) = 2.50Δ, 36.9° down from base in.

Prism calculator →

Resolving prism

H = R × cos θ

V = R × sin θ

θ in 360° notation: 0° to the examiner's right, 90° up. For OS, 0° is base out; for OD, 0° is base in. A negative H points toward 180°; a negative V is base down.

Example: OS 4.00Δ base 30°: H = 4.00 × cos 30° = 3.46Δ BO, V = 4.00 × sin 30° = 2.00Δ BU.

Prism calculator →

Splitting prism between the eyes

Horizontal: same base direction in both eyes

Vertical: opposite base directions

Example: 5Δ BO = 2.5Δ BO OD + 2.5Δ BO OS. 3Δ BU OD = 1.5Δ BU OD + 1.5Δ BD OS.

Prism and Prentice's rule →

Vertical imbalance at the reading level

Imbalance = c × (difference between the two 90° powers)

c = reading depth below the optical centers, in cm. Keep the signs: with one plus and one minus lens the powers add. Consider slab-off at about 1.5Δ: a conventional slab-off (base up) goes on the lens that is more minus (least plus) at 90°, a reverse slab-off (base down) on the more plus lens.

Example: OD -1.00 -0.50 × 180 (-1.50 D at 90°), OS -3.75 -0.50 × 090 (-3.75 D at 90°), reading 10 mm down: 1.0 × 2.25 = 2.25Δ; slab-off would go on OS.

Prism and Prentice's rule →

Measurements and fitting

Decentration

Frame PD = A + DBL

Decentration per lens = (frame PD − patient PD) ÷ 2

With monocular PDs: frame PD ÷ 2 − monocular PD

A positive result: the optical centers move in (nasally). Negative: they move out (temporally).

Example: A 50, DBL 20, PD 63: frame PD 70 mm, 3.5 mm in per lens.

Decentration calculator →

Minimum blank size

MBS = ED + 2 × decentration per lens + 2 mm

Use the amount of decentration, in or out, ignoring the sign; with monocular PDs, use the lens that decenters more. The 2 mm allows for edging and chips; some questions leave it out.

Example: ED 56 mm, 3.5 mm decentration: 56 + (2 × 3.5) + 2 = 65 mm.

Minimum blank size calculator →

Seg drop

Seg drop = B ÷ 2 − seg height

With the optical center at the boxing center.

Example: B 38 mm, seg height 17 mm: 19 − 17 = 2 mm below the optical center.

Patient measurements and fitting →

Seg inset

Seg inset per lens = (distance PD − near PD) ÷ 2

Total inset = decentration + seg inset

Seg inset is measured from the distance optical center; total inset from the boxing center.

Example: Distance PD 63 mm, near PD 60 mm: (63 − 60) ÷ 2 = 1.5 mm per lens. In the 70 mm frame above, total inset = 3.5 + 1.5 = 5.0 mm.

Patient measurements and fitting →

Pantoscopic tilt rule

Lower the optical center 1 mm for each 2° of tilt

Single-vision lenses only: a progressive fitting cross stays at the pupil center, a bifocal seg top at the lower lid.

Example: Pupil height 23 mm, 8° tilt: 23 − (8 ÷ 2) = 19 mm optical center height.

Pantoscopic tilt guide →

Lens thickness

Sag formula

r = (n − 1) ÷ |F|, in meters (× 1000 for millimeters)

s = r − √(r² − y²) ≈ y² ÷ 2r, with y = diameter ÷ 2

Minus lens: edge ≈ center + s

Plus lens: center ≈ edge + s

Work in millimeters: r, y and s all in mm.

Example: -5.00 D polycarbonate (n = 1.586), 60 mm, 1.5 mm center: r = 0.586 ÷ 5.00 = 117.2 mm, s = 3.90 mm, edge ≈ 5.40 mm.

Lens thickness calculator →

ANSI Z80.1-2020 tolerances

The power table is for single-vision and lined multifocal lenses; progressives have their own distance-power tolerances. A 2025 edition revised the summary table; check which edition your exam uses.

Power
ItemOrdered powerTolerance
Sphere0.00 to ±6.50 D±0.13 D
SphereOver ±6.50 D±2%
Cylinder0.00 to 2.00 D±0.13 D
CylinderOver 2.00 to 4.50 D±0.15 D
CylinderOver 4.50 D±4%
AddUp to +4.00 D±0.12 D
AddOver +4.00 D±0.18 D
Cylinder axis
Ordered cylinderAxis tolerance
0.25 D or less±14°
Over 0.25 to 0.50 D±7°
Over 0.50 to 0.75 D±5°
Over 0.75 to 1.50 D±3°
Over 1.50 D±2°
Unwanted prism
CheckPower in that meridianTolerance
Horizontal, mounted pair0.00 to ±2.75 D0.67Δ total imbalance
Horizontal, mounted pairOver ±2.75 DPRPs within ±2.5 mm of the ordered distance PD
Vertical, mounted pair0.00 to ±3.375 D0.33Δ imbalance
Vertical, mounted pairOver ±3.375 DPRP heights no more than 1.0 mm apart

ANSI Z80.1 standards and tolerances →

Put the formulas to work.

Try them on exam-style questions in the free ABO practice test, or check your answers with the optical calculators.

Take the free practice test →